Program MSDN/DPNSS trunks

Before You Begin

Programming

To program MSDN/DPNSS trunks:

  1. Link Descriptor Assignment form
    Enter "A" or "B" in the Address for Message Control field.
    Enter "DPNSS" in the Integrated Digital Access field.

  2. Digital Link Assignment form
    Enter the Digital Link Descriptor Number programmed in step 1.

  3. Class of Service Options Assignment form
    Set the ANI/DNIS ISDN Number Delivery Trunk field to "Yes".

  4. MSDN-DPNSS-DASS II Trunk Circuit Descriptor Assignment form
    Select "CEPT" or "DS1" from the Card Type field if cards are installed in DSU cabinet.
    Enable "Incoming" or "Outgoing" from the Dual Seizure Priority field.
    Select "MAIN PBX" from the Far End Connection field.
    Enable "MSDN-DPNSS" from the Signaling Protocol field.

  5. Trunk Service Assignment form
    Enter the COS number programmed in step 3.
    Complete the Non-dial in Trunks Answer Point fields.
    Complete the Dial in Trunks: Incoming Digit Modification fields.

  6. Digital Trunk Assignment form
    Complete the Trunk Number, Trunk Service Number (from step 5), Circuit Descriptor (from step 4), and Interconnect Number fields.

  7. Network Synchronization form (optional)
    Assign a source connection to a Network Source Clock.