The Digital DID Trunk Circuit Descriptor Assignment form is used to assign signaling and timing parameters to groups of DS1 DID trunk circuits using channel associated signaling (CAS).
Use this form when performing the following tasks:
Parameter |
Description |
Default Value |
Number |
Enter a number from 1 to 32 to uniquely identify each entry. |
Blank |
Ignore Far End Disconnect |
Select "Yes" or "No" to indicate whether the trunks are to ignore or respond to a far-end disconnect signal. |
No |
Release Acknowledge Timer |
Enter the amount of time the system will wait for a release acknowledgement from the far-end. Allowed values are 40 - 9000 units (200 ms - 450 sec), each unit being equal to 50 ms. |
(80 UNITS) 4s |
Address Signaling |
Select the appropriate value to indicate the type of signaling used.
|
DTMF |
Incoming Start Type |
Select the appropriate value to indicate whether the trunk is immediate, delay dial, or wink start on incoming calls. Applies only to DS1 DID trunks. |
Wink |
Far End Connection |
Not applicable to this release. |
Local Office |
Flash Timer |
Enter a value between "200" and "700" milliseconds in increments of 50 milliseconds. This timer specifies the duration of the single trunk flash or each of the flashes for a double trunk flash. For a double flash, the time between flashes is hard-coded at one second. |
300 ms |